Home > Products > Shielded cable >
Mine control shielded cable
Product Details
Mine control shielded cable
The flame-retardant control cable MKVVP (2-37 cores) X (0.5-2.5) for mining purposes is laid in urban areas, cable trenches, pipelines, direct burial, and hanging, and can withstand significant external mechanical forces in fixed applications.
MKVV copper-core PVC J-type PVC sheathed flame-retardant control cable for coal mines (2-37 cores) × (0.75-2.5mm2) is laid indoors, in cable trenches, pipelines, and other fixed locations.
MKVV22 copper-core PVC J-type PVC sheathed steel tape armored flame-retardant control cable for coal mines (2-37 cores) × (0.75-2.5mm2) is laid indoors, in cable trenches, in pipelines, in direct burial, and in other fixed locations that can withstand significant mechanical tension.
MKVV32 Copper-core PVC J-type PVC sheathed thin steel wire armored flame-retardant control cable for coal mines (2-37 cores) × (0.75-2.5mm2)
KVVP (1.0-2.5mm2) 4-30-core copper-core PVC-J insulated PVC sheathed braided shield control cable;
KVVP2 (0.75-10mm2) 4-37-core copper-core PVC J-type PVC sheathed copper tape shielded control cable;
KVV22 (0.75-10mm2) 4-37-core copper-core PVC J-type PVC sheathed steel tape armored control cable;
KVVR (0.75-10mm2) 4-37-core copper-core PVC J-type PVC sheathed control flexible cable;
KVVRP (1.0-2.5mm2) 4-30-core copper-core PVC J-type PVC sheathed braided shield control flexible cable;
KVVP-22 (1.0-2.5mm2) 4-30-core copper-core PVC J-type PVC sheath copper wire braided shield steel tape armor;
KVVP2-22 (0.75-10mm2) 4-37-core copper core PVC J-type PVC sheath copper tape shield steel tape armor;
KVV-SA (0.75-10mm2) 4-37-core copper-core PVC J-type PVC sheathed control cable;
KVV-DA (0.75-10mm2) 4-37-core copper-core PVC J-type PVC sheathed control cable;
KVVRT (0.75-10mm2) 4-37 core copper core PVC J-type PVC sheathed control flexible cable;
Service characteristics: The long-term allowable operating temperature for the conductor of control cables used in coal mines is 70℃, and the laying temperature of the cable should not be lower than 0℃. The allowable bending radius for control cables used in coal mines is as follows: for cables with armor or copper tape shielding structure, it should not be less than 12 times the outer diameter of the cable; for flexible cables with shielding layer structure, it should not be less than 6 times the outer diameter of the cable; for cables without armor layer, it should not be less than 6 times the outer diameter of the cable.