RVVP shielded cable

Product Details

Cross-sectional area: 0.5-25mm².


Flame retardant properties: IEC 60332.1.


Test voltage: 2000V, for 5 minutes.


Insulation resistance: >20MΩ×KM.


Operating temperature (fixed installation): -30~ +70℃.


Operating temperature (mobile installation): -5~ +70℃.


Bending radius: 15 times the cable outer diameter.


Rated voltage: 300V/500V Conductor: multi-strand copper conductor, compliant with Class 5 of GB/T 3956 (equivalent to IEC60228.5).


Insulation: Polyvinyl chloride (PVC) compound.


Shielding: Tinned copper wire braided shielding, with a braiding density greater than 85%


Sheath: flexible PVC compound, gray (RAL7001).


Core wire identification: ≤5 cores, colored core wires; black core wires with white numerical numbers, may include yellow-green ground wires.


Number of core wires: 2-24 cores.


Reference standards: JB8734, VDE 0281.


Packaging specifications: 100m, 500m, 1000m.


Scope of application


Compared to RVV cables, RVVP cables feature copper wire braided shielding, offering superior electromagnetic compatibility. Therefore, they are particularly suitable for installation sites with harsh electromagnetic environments and limited installation distances. RVVP cable products can be installed in trays and hoses for indoor installation.


Related Products